Application
Mining explosion-proof and intrinsically safe low voltage AC soft starter (hereinafter referred to as starter). The device PLC is the control core, and the 7-inch Chinese embedded computer is used as the human-computer interaction interface. Support Profibus-DP, industrial Ethernet communication, can achieve centralized control with the ground control center network.
Product features
•The soft starting driver adopts WTR-200 controller, and the soft starting performance is stable and reliable, and has the double protection of soft starting and straight up.
•The starting parameters can be set flexibly according to different loads, and the optimal current curve and torque control characteristics can be obtained.
•The starting current can be adjusted according to the load, the starting loss is reduced, the optimum torque is generated at the minimum current.
•The pilot circuit of the equipment is an intrinsically safe circuit, which can effectively prevent the occurrence of spontaneous starting accident caused by short circuit or grounding of the control line.
•Siemens PLC is used as the control core, which can easily realize the centralized control of networking and support
Profibus-DP, industrial Ethernet communication.
•The embedded human-computer interaction interface can display the operating conditions of each unit, motor current, voltage real-time display and fault status display, and has the functions of fault record query, current, voltage curve query and so on.
•Each drive circuit has an independent monitoring and protection unit, which is not affected by each other, and only
transmits data and instructions to each other through the formation of the field bus ring network with the superior plc core unit. The utility model has the advantages of high degree of automation, convenient and intuitive man-machine conversation, stable performance, sensitive protection, reliable action and so on.
•Each unit of the equipment adopts drawer plug-in type, which has good interchangeability and consistency.
•Keyboard operation, convenient and beautiful.
* Rated operational voltage: 1140V, 660V
* Rated operational current: 1600A, 800A
* Intrinsically safe parameter:
U10: AC22V/DC15V;I10:AC123mA/DC45mA
* Maximum power of motor controlled by each unit at rated voltage of
1140V: 590kW, soft start time:1~180s
* Operation frequency: At the maximum condition, 12 times/Hour
* Cooling-down method: Air convective cooling
* Control mode: Security remote control, proximity, network control