other
Products

Mining Flameproof and Intrinsically Safe Type Multi-Loop High-Voltage Vacuum Electromagnetic Switch

Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
  • Brand:

    WANTAI
  • Item NO.:

    QJZ-ML004
  • Order(MOQ):

    1
  • Payment:

    T/T, L/C, etc.
  • Market Price:

    55000
  • Price:

    $52888/Set
  • Price Range:

    5 - 10
  • Product Origin:

    China
  • Color:

    Optional
  • Shipping Port:

    China port
  • Lead Time:

    30 days
  • Weight:

    2850000
QJGZ-800~2400/2~10
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter

Application
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
Technical Parameters
Model QJGZ-2400/3300-8, 9, 10 QJGZ-1600/3300-6 QJGZ-800/3300-4, 2
rated operational current 2400A 1600A 800A
Number of output loops 8, 9, 10 6 4, 2
Vacuum isolation phase changer 3 Lines(Each line 800A) 2 Lines(Each line 800A) 1 Lines(Each line 800A)
Shape size including cable connector 3100*704*1219 3100*704*1219 1605*718*1205
Rated operational voltage 3300V  50Hz
vacuum contactor Single circuit maximum rated current:400A
Input and output mode Cable connector
Protection function Leakage, leakage locking, insulation monitoring, overload, short circuit, overvoltage, undervoltage, phase break
Fault query Query and store fault information for 30 days at any time
Display module The man-machine interface adopts embedded system, and the running condition is monitored dynamically.
Communication mode RS485,CAN Bus, Ethernet
Control mode Proximity control, security remote control, network control
Related Products
combination switch
Mine Explosion-Proof Intrinsically Safe Multi Circuit Vacuum Starter
QJZ3-2400/1140(660)-8ML  mine explosion-proof and intrinsically safe type multi-loop  vacuum electromagnetic starter , it is applicable to the mine with explosive gas and coal dust. In the circuit with AC 50Hz and rated voltage of AC 1140 (660) V, it can control and protect the starting and stopping of 8  or less three-phase squirrel cage asynchronous motors at the same time, and can change the phase sequence when stopping. It is especially suitable for centralized monitoring of mining, transportation, mining and other working faces with concentrated power load.
combination switch
Explosion-Proof and Intrinsically Safe Type Multi-Loop High-Voltage Vacuum Electromagnetic Switch for Mine
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
combination switch
Mining Explosion-Proof and Intrinsically Safe Type Multi-Loop High-Voltage Vacuum Electromagnetic Switch
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
Mining high-voltage vacuum electromagnetic starter
Mine Explosion-Proof and Intrinsically Safe Multi Circuit High Voltage Vacuum Electromagnetic Combination Switch
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
combination switch
Mining Explosion-Proof and Intrinsically Safe Type Multi-Loop High-Voltage Vacuum Electromagnetic Switch
Mining explosion-proof and intrinsically safe type multi-loop high-voltage vacuum electromagnetic starter is suitable for coal mine AC 3300V, frequency 50Hz, three-phase neutral point unearthed power supply system, local or remote control of three-phase asynchronous electric drive, to realize the centralized control of shearer, scraper conveyor, crusher, transfer machine, pumping station and other equipment in comprehensive mechanized coal mining face.
Intrinsically Safe Vacuum Feed Switch
Mine Use Intrinsically Safe Vacuum Feed Switch For Coal Mining
Application: Used in coal mines, in AC 50Hz, rated voltage of 660V or 1140V, rated current to800, 1000A three-phase neutral point undergrounded power supply system, as a main switch or branch switch, but also as a large-capacity motor infrequently for starting control.
Electrical Equipment
Mining General Low Voltage Switchgear
Mining general low-voltage switchgear can be used as a complete set of low-voltage power distribution equipment in the 690V and 400V power supply system of substations in underground coal mines, underground yards without gas and coal dust explosion hazards, workshops with heavy dust corrosion, and wet places of metallurgy, subway and low buildings. 
Starter
Explosion-proof reversible starter for mining
This product is suitable for an environment with coal mine gas, coal dust, and other explosive gases underground, to logically control the start, stop and double-speed of the three-phase AC asynchronous motor or AC double-winding motor in the circuit of AV 1140V or 660V. And it has a joint control function.
We are committed to providing safe, energy-saving, efficient products and system solutions for intelligent mines.

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsapp